Skip to main content

Condo Flooring: Rules, Sound Ratings and Your HOA

What IIC and STC sound ratings mean, what the Florida Building Code sets between units, and how to check your condo or HOA rules before you order a floor.

If you live in a condo, the floor you put down is partly your neighbor’s business. Footsteps, a dropped pan and a rolling chair all travel down into the unit below. That is why many condo associations have rules about floors, and why those rules often talk about two numbers: IIC and STC.

This guide explains what those numbers mean, what Florida’s building code sets between units, and how the rules differ between a condo and a homeowners association. We install floors, so we are not a neutral party. Every rule below is linked to the law or code it comes from, so you can read it yourself.

One thing first. We cannot tell you what your association requires. Only your own documents and your association can. What we can do is help you ask the right questions before you order anything.

IIC and STC in plain words

Both numbers rate how well a floor and ceiling between two homes block sound. The Florida Building Code names them in Section 1207, under the heading Sound Transmission.

  • STC stands for sound transmission class. The code puts it under airborne sound. In plain terms, that is sound traveling through the air, like voices or a TV.
  • IIC stands for impact insulation class. The code puts it under structure-borne sound. In plain terms, that is sound from something hitting the floor, like footsteps or a dropped spoon.

For both, a higher number means more sound is blocked.

Footsteps are the kind a neighbor below hears every day, so it is worth asking your association which of the two numbers it cares about, or whether it wants both.

What Florida's building code sets between units

  • Scope: the section covers walls, partitions and floor and ceiling assemblies between dwelling units, and between units and shared spaces such as halls and stairways (FBC 1207.1).
  • Airborne sound: an STC of not less than 50 when tested to ASTM E90, or a field rating (NNIC) of not less than 45 when tested in place to ASTM E336 (FBC 1207.2).
  • Impact sound: floor and ceiling assemblies between units need an IIC of not less than 50 when tested to ASTM E492, or a field rating (AIIC) of not less than 45 when tested in place to ASTM E1007 (FBC 1207.3).
  • Your association can ask for more. Its number, if it has one, is in its own documents.

The number is for the whole floor, not the plank

Read the code closely and you will see it rates floor and ceiling assemblies. That means everything between your feet and your neighbor’s ceiling: the finished floor, what is under it, the concrete and whatever hangs below.

So a sound number printed on a box of flooring is not the whole story. Ask the maker or seller what assembly the number was tested on. A rating measured on one kind of slab with one kind of ceiling below may not match your building.

This is also why the code allows two kinds of results. A lab test, like ASTM E492, measures a sample assembly. A field test, like ASTM E1007, measures the real floor in the real building, and the code accepts a lower number for it: 45 instead of 50.

What is under the floor matters most

In most condo buildings the concrete is already there, so the part you control is the layer between the slab and your new floor. That layer is the underlayment.

For vinyl plank, MSI, a flooring maker, says many products are installed with a padded underlayment that adds cushioning and reduces noise transfer. The same MSI article says carpet’s plush texture makes it popular where sound absorption is a priority.

Tile and stone can go in a condo too. With a hard floor, the sound layer under it does the work, and the association may want to see what it is. Ask for the product sheet for the underlayment or sound mat, with its test results, before you buy.

Questions to ask about the layer under the floor

  • What underlayment or sound mat goes under this floor, and is it one the flooring maker allows?
  • What IIC and STC numbers were measured with it, and on what assembly?
  • Was that a lab number or a field number?
  • Does my association accept that product, or does it keep a list?

Condo rules and HOA rules are not the same

People use “HOA” for every kind of association, but Florida law treats them differently. Condominiums fall under chapter 718 of the Florida Statutes. Homeowners associations for single family homes and villas generally fall under chapter 720.

In a condo

Condo owners share walls, floors and ceilings, so floor rules are common. Florida’s condo law puts a lot of weight on the declaration, the founding document of the condo. For example, section 718.113 says there shall be no material alteration of the common elements except in the manner the declaration provides.

Whether your floor touches the common elements, and what your condo’s rules say about floors, is in your own declaration, bylaws and rules. Read those first. If you cannot find a floor rule, ask the association in writing what it requires before work starts.

In an HOA community

A single family home or villa does not usually sit on top of a neighbor, so sound between units is rarely the issue. Florida’s HOA law also sets limits on what an association can control inside a home.

Section 720.3035 says an association’s power to review and approve improvements is allowed only to the extent the declaration states it or it can be reasonably inferred. It also says an association may not enforce or adopt a rule that “Limits or places requirements on the interior of a structure that is not visible from the parcel’s frontage or an adjacent parcel, an adjacent common area, or a community golf course.”

That is the law’s own wording, and we are not lawyers. Communities differ, and the type of home does not always tell you which law applies. If you are not sure which law covers your home, your association or a lawyer can tell you.

The 55+ communities around Trinity

Andy has told us about the retirees we work for around Trinity, and he named Heritage Springs, a gated 55+ community in Trinity, when he did.

We have not found a published flooring rule for Heritage Springs, and we will not guess at one. The same goes for any community. If you live in one, your association’s documents are the place to look, and the office or manager can tell you whether a new floor needs a form.

How to read a sound rating on a product sheet

When a seller hands you a sheet with an IIC or STC number, a few lines on it tell you whether it fits what your association asked for. You do not need to understand the test to check them.

  • The test name. The code names ASTM E492 for a lab IIC number and ASTM E1007 for a field number. For STC it names ASTM E90 in the lab and ASTM E336 in the field. If the sheet names none of these, ask what test was used.
  • Lab or field. A field result is written with its own name, AIIC for impact or NNIC for airborne. The code accepts 45 for a field result and 50 for a lab result, so check which one your association means when it gives you a number.
  • The assembly. The sheet should say what the sample was: how thick the concrete was, what underlayment was used, and whether there was a ceiling below. If your building is different, the number may be different too.
  • The exact product. A rating for one underlayment does not carry over to another one, even from the same maker. Match the name on the sheet to the name on the box.

Bring the sheet to your association with your request. It is easier for a board to say yes to a number it can check.

A simple plan before you order

Here is the order we would follow in a condo or HOA home:

  1. Find your declaration, bylaws and rules, and search them for “floor”, “sound”, “IIC”, “STC” and “underlayment”.
  2. Ask the association in writing whether a new floor needs approval, and what it needs to see.
  3. Pick the floor, then pick the underlayment that goes with it, and get the product sheets with test results.
  4. Send the association what it asked for and keep a copy of the answer.
  5. Ask whether the building has rules for work hours, elevator use or where the old floor can go.

If your association asks for an IIC or STC number, compare it to the product sheet for the exact assembly, not the flooring alone.

Which floors people choose in condos

There is no single right floor. It depends on what your association allows and how you live.

  • Vinyl plank is a common pick, and many products go down with a padded underlayment that reduces noise transfer, per MSI. Our luxury vinyl plank page says more.
  • Carpet absorbs sound, which is why MSI calls it popular where sound absorption is a priority.
  • Tile and stone can work with the right sound layer under them, if the association allows it.

Our flooring installation page covers every floor we install, and our guide to porcelain tile or vinyl plank for a Florida home compares the two most common picks.

Planning a new floor in a condo or HOA home? Tell us what your association asks for.

Call (727) 376-3333 Or get a free estimate

Where we work

We work from Odessa, in Pasco County, and take on flooring jobs across Pasco, Pinellas and Hillsborough, including homes around Trinity's retirement communities. Tell us what kind of home you have and what floor is there now.

About the author

Andy's crew installs tile, wood, carpet and vinyl plank floors. Andy Tsiouklas is the owner of Trinity Tile and Stone. In Andy's words: "My father has been in the construction field all his life, and I ended up going the same route he did, keeping it in the family."

More about Andy and the company

Related work

These are the floors condo and HOA owners ask us about most, and each page says more about the work.

Have your association's rules in hand? Call us and we can talk through floors that fit them.

Call(727) 376-3333

Or get a free estimate

Call Now Get a Free Estimate